Rockwell Automation 1333 Drive, 3/4-5HP, 230-575V Series D User Manual
Rockwell Automation Equipment
Table of contents
Document Outline
- 1333-5.2, Bulletin 1333 3/4-20 HP (.55-15 kW) Adjustable Frequency AC Drive (Series D), User Manual
- Important User Information
- Summary of Changes
- Table of Contents
- Preface - Manual Objective
- Repair or Repair/Exchange Procedure
- 1 - Pre Installation Care
- 2 - Drive Identification
- 3 - Specifications
- Operating Environment
- Storage Environment
- Enclosure
- Input Power Specifications
- Standard Three Phase Data Input Current, Output Current and kVA
- Load Requirements
- Output Power Specifications
- Frequency Control Inputs
- Required Control Inputs
- Optional Remote Control Inputs
- Contact Outputs
- Analog Outputs
- Drive Displays
- 4 - Installation and Wiring
- General Input Power Conditioning
- ZAA CAA 230V Dimensions, Weights and Conduit Entry Locations
- DAA GAA 230V Dimensions, Weights and Conduit Entry Locations
- AAB CAB 460V Dimensions, Weights and Conduit Entry Locations
- General Wiring Procedures
- Wire Group Numbers
- Terminal Block Power Wiring
- 3/4 5 HP (.55 4 kW) Terminal Block Power Wiring
- 7 1/2 20 HP (5.5 15 kW) Terminal Block Power Wiring
- ZAA EAA 3 Phase Power Terminal Block Wiring
- FAA or GAA 3 Phase Power Terminal Block Wiring
- If You Use FAA or GAA Units
- ZAA EAA 1 Phase Power Terminal Block Wiring
- FAA or GAA 1 Phase Power Terminal Block Wiring
- If You Use FAA or GAA Units
- Control and Signal Wiring
- Terminal Block
- 5 - Operation and Programming
- Local Control and Programming Panel
- The Controls
- The Displays
- Programming the Drive
- Accel and Decel Settings
- Volts per Hertz Curve Settings
- DC Boost Settings
- Overload Protection Settings
- Local/Remote Control Enable
- Local/Remote Speed Enable
- Reverse Enable
- Stop Settings
- DC Brake Settings
- Max Speed Settings
- Accel and Decel Hold Enable
- Preset Frequency and Aux Accel/Decel Enable
- Aux Interlock Enable
- Drive Supplied Contact Settings
- Jog Settings
- Preset Frequency Settings
- Auxiliary Accel and Decel Settings
- Skip Frequency Settings
- Current Limit Setting
- Auto Restart Settings
- Lower and Upper Frequency Clamp Settings
- Bias and Gain Settings
- Output Meter Settings
- Monitoring Mode Settings
- Drive Fault Memory
- 6 - Startup
- A - Bulletin 1333 Options
- B - Preventive Maintenance and Troubleshooting Common Drive Problems
- C - Factory and Field Parameter Settings
- D - Application Data
- We Want Our Manuals to be the Best!
- Business Reply Mail
- Back Cover