Rockwell Automation 1333 Drive, 3/4-5HP, 230-575V Series D User Manual
Page 13

Specifications
Chapter 3
3-2
Standard ThreeĆPhase Data
Input Current, Output Current
and kVA
200/208/230V AC, 3ĆPhase, 50/60 Hertz Input Voltage
200VĂAC 208VĂAC 230VĂAC
200VĂAC 208VĂAC 230VĂAC Total Heat
Rating Nominal Input Input
Input
Input Output Output Output Output Dissipated
Code
HP kW Amps kVA
kVA
kVA
Amps
kVA
kVA
kVA
Watts (BTU/hr)
ZAA
3/4 .55
4.1
1.4
1.5
1.6
3.2
1.1
1.2
1.3
80
273
AAA
1
.75
6.5
2.3
2.4
2.6
5.0
1.7
1.8
2.0
100
341
YAA
2
1.5
9.0
3.1
3.2
3.6
8.0
2.8
2.9
3.2
170
580
BAA
3
2.2 14.0
4.8
5.0
5.6
11.0
3.8
4.0
4.4
250
853
CAA
5
4 22.0
7.6
7.9
8.8
17.5
6.1
6.3
7.0
360 1228
DAA
7Ă1/2 5.5 27.0
9.3
9.7
10.8
24.0
8.3
8.7
9.7
425 1449
EAA
10 7.5 37.0 12.8
13.3
14.7
33.0
11.5
11.9
13.3
480 1637
FAA
15
11 47.0 16.3
16.9
18.8
45.0
15.6
16.2
18.1
565 1927
GAA
20
15 62.0 21.5
22.3
24.7
61.0
21.1
22.0
24.6
610 2080
380/415/460V AC, 3ĆPhase, 50/60 Hertz Input Voltage
380VĂAC 415VĂAC 460VĂAC
380VĂAC 415VĂAC 460VĂAC Total Heat
Rating Nominal Input Input
Input
Input Output Output Output Output Dissipated
Code
HP kW Amps kVA
kVA
kVA
Amps
kVA
kVA
kVA
Watts (BTU/hr)
AAB
1
.75
3.3
2.2
2.4
2.6
2.1
1.4
1.5
1.7
100
341
YAB
2
1.5
4.5
3.0
3.2
3.6
4.0
2.6
2.9
3.2
170
580
BAB
3
2.2
8.0
5.3
5.8
6.4
6.0
3.9
4.3
4.8
250
853
CAB
5
4 13.0
8.6
9.3
10.4
9.4
6.2
6.8
7.5
370 1262
Derated SingleĆPhase Data ❶
Input Current, Output Current
and kVA
200/208/230V AC, 1ĆPhase, 50 Hertz Input Voltage
200VĂAC 208VĂAC 230VĂAC
200VĂAC 208VĂAC 230VĂAC Total Heat
Rating Nominal Input Input
Input
Input Output Output Output Output Dissipated
Code
HP kW Amps kVA
kVA
kVA
Amps
kVA
kVA
kVA
Watts (BTU/hr)
ZAA
1/2 .37
5.7
1.1
1.2
1.3
2.4
0.8
0.9
1.0
80
273
AAA
3/4 .55
7.7
1.5
1.6
1.8
3.4
1.2
1.2
1.4
100
341
YAA
1
.75
8.8
1.8
1.8
2.0
4.5
1.6
1.6
1.8
170
580
BAA
1Ă1/2 1.1 11.9
2.4
2.5
2.7
5.4
1.9
1.9
2.2
250
853
CAA
2
1.5 17.3
3.5
3.6
4.0
7.7
2.7
2.8
3.1
360 1228
DAA
3
2.2 21.4
4.3
4.5
4.9
11.0
3.8
4.0
4.4
425 1449
EAA
5
4 29.1
5.8
6.1
6.7
15.0
5.2
5.4
6.0
480 1637
FAA
7Ă1/2 5.5 38.0
7.6
7.9
8.7
21.0
7.3
7.6
8.4
565 1927
GAA
10 7.5 49.3
9.9
10.3
11.3
28.0
9.7
10.1
11.2
610 2080
200/208/230V AC, 1ĆPhase, 60 Hertz Input Voltage
200VĂAC 208VĂAC 230VĂAC
200VĂAC 208VĂAC 230VĂAC Total Heat
Rating Nominal Input Input
Input
Input Output Output Output Output Dissipated
Code
HP kW Amps kVA
kVA
kVA
Amps
kVA
kVA
kVA
Watts (BTU/hr)
ZAA
1/2 .37
6.2
1.2
1.3
1.4
2.6
0.9
0.9
1.0
80
273
AAA
3/4 .55
8.6
1.7
1.8
2.0
3.8
1.3
1.4
1.5
100
341
YAA
1
.75
9.5
1.9
2.0
2.2
4.9
1.7
1.8
2.0
170
580
BAA
1Ă1/2 1.1 13.0
2.6
2.7
3.0
5.9
2.0
2.1
2.4
250
853
CAA
2
1.5 18.8
3.8
3.9
4.3
8.4
2.9
3.0
3.3
360 1228
DAA
3
2.2 23.4
4.7
4.9
5.8
12.0
4.2
4.3
4.8
425 1449
EAA
5
4 31.1
6.2
6.5
7.1
16.0
5.5
5.8
6.4
480 1637
FAA
7Ă1/2 5.5 41.6
8.3
8.7
9.6
23.0
10.0
8.3
9.2
565 1927
GAA
10 7.5 54.6 10.9
11.4
12.6
31.0
10.7
11.2
12.3
610 2080
❶
.200/208/230VĂAC units may be derated for single phase input power The single phase will not appear on
the shipping carton label or the drive nameplate.