Safety information, Optical ports, Laser radiation ports – Rockwell Automation 1441-DYN25-Z Dynamix 2500 Data Collector User Manual
Page 15: Dynamix 2500 data collector kit parts list, Optical ports laser radiation ports

Rockwell Automation Publication 1441-UM001B-EN-P - September 2012
15
The Dynamix 2500 Data Collector Chapter 1
Safety Information
Be aware of these safety precautions.
Optical Ports
Laser Radiation Ports
Dynamix 2500 Data
Collector Kit Parts List
This table list the parts list for the data collector kit.
The Dynamix 2500 data collector, catalog number, 1441-DYN25-Z-2C, is for
ATEX Zone 2 and IECEx for hazardous environments. This kit contains the
same parts as the Dynamix 2500 data collector,
catalog number 1441-DYN25-2C except 1441-DYN25-Z replaces 1441-
DYN25.
IMPORTANT
Avoid Water
The Dynamix 2500 data collector is splash and dust resistant. However,
avoid direct contact with water, wet surfaces, or condensing humidity.
Keep this instrument away from wet locations, for example, laundry, wet
basements, swimming pools.
If the data collector subject to these conditions, adverse operation may
result. Before you use it, let the instrument dry thoroughly before
operating.
ATTENTION: To avoid damage or injury, place the Dynamix 2500 data
collector on a solid stable surface when not in use and do not place any
heavy objects on it. Use only the accessories recommended by Rockwell
Automation. Keep liquids and foreign objects away from the instrument,
and never operate it if any liquid or foreign object has entered it.
ATTENTION: When the laser on the data collector is active, viewing the
laser beam can expose your eyes beyond the maximum permissible
exposure recommendations and cause harm.
ATTENTION: Class 1 laser product. Laser radiation is present when the
system is open and interlocks bypassed. Only trained and qualified
personnel should be allowed to install, replace, or service the instrument.
Table 2 - Dynamix 2500 Data Collector Kit Parts List, 1441-DYN25-2C
Catalog No.
Description
1441-DYN25-Z
Dynamix 2500 data collector
1441-DYN25-CAP
Dust Cap Set for Inputs
1441-DYN25-CD
Operating System and Documentation CD
1441-DYN25-PS
Global Power Supply
1441-PEN25-BAT
Battery
1441-PEN25-CASE-T
Transit Case
1441-PEN25-COMS-US
Communication Cable USB Power Splitter
1441-PEN25-HS
Hand Strap
1441-PEN25-RBS
Rubber Bump Sleeve