Gate interface board, Remove components – Rockwell Automation PF700 PowerFlex 700 Drive Components Replacement - Frame 9 User Manual
Page 58
![background image](/manuals/576918/58/background.png)
58
Rockwell Automation Publication 20B-IN025B-EN-P - January 2011
Chapter 3 Component Replacement Procedures
8.
Install the Gate Interface Board:
a. Install the Gate Interface Board using the four nuts removed previously.
Torque screws to 2.9 N•m (26 lb•in).
b. Install the supplied Gate Interconnect Harness.
c. Connect wiring between the IGBT and Gate Interface Board as shown
in
Gate Interface Board on page 58
d. Connect wires to the Current Transducer.
9.
Install the three Snubber Capacitors in the reverse order of
Remove all
IGBT Snubber components: on page 29
.
Torque nuts to 5.6 N•m (50 lb•in).
10.
Reassemble remaining components in reverse order.
11.
Replace all safety shields and enclosure covers before applying power to the
drive.
Gate Interface Board
See
Chapter 1 - Drive Components
to locate the component detailed in these
instructions.
Remove Components
1.
Read and follow the
Safety Precautions on page 8
and
Important Initial
Steps on page 10
.
2.
Locate the Gate Interface Board to be replaced.
3.
Remove the safety cover over the Gate Interface Board.
4.
Label and disconnect all wires.
Connector
Wire Color(s)
Connects To:
J1
Red/White/Black
J1 on IGBT
J2
Red/White/Black
J2 on IGBT
J3
Red/White/Black
J3 on IGBT
J4
Orange/Black
J23 on Power Interface Board
J5
Blue/White
J18 on Power Interface Board
J6
Red/White
J4 on IGBT
J7
Red/White/Black
J7-W to J7-V (Gate Interface Boards W and V)
J7-V to J7-U (Gate Interface Boards V and U)
J7-U to J8 on Power Interface Board
J8
Black
J8-W to J8-V (Gate Interface Boards W and V)
J8-V to J8-U (Gate Interface Boards V and U)
J8-U to J6 on Power Interface Board