Table 15. MSS-200 Troubleshooting

LED's

Symptom

Possible Problem

Solution

8

4

2

1

No oil pressure or over-

speed

O/S to Oel jumper wire not connected?

Check jumper wire from

O/S to Oel terminal.

1

4

2

8

Defective alternator or pick-

up, wire breakage or V-Belt

breakage.

MS-200 is not receiving a frequency signal? Check wiring (input signal)

4

2

8

1

Engine did not reach the

set engine speed within 30

seconds

Is programmed value correct?

Re-program value

2

8

1

4

Cannot read sensor inputs.

Electrical short, wire breakage, or defective

transistor?

Check wiring, sensor

components.

2

8

4

1

Incorrect alternator or oil

pressure switch reading

Is programmed value correct?

Re-program value

2

4

1

8

All engine start attempts

failed.

Defective fuel filter?

Empty fuel tank?

Clean or replace fuel filter.

Check fuel level.