beautypg.com

Programming guide, Table 12. programming guide – Multiquip AP6 Series User Manual

Page 41

background image

AP6/AP8 SERIES TRASH PUMPS • OPERATION AND PARTS MANUAL — REV. #0 (06/11/14) — PAGE 41

PROGRAMMING GUIDE

Table 12. Programming Guide

Number Of

Pushes Of

OFF/SET

Button

Button To

Push

Parameters

LED

Multiplier

Factory

Setting

Range

Decrease

Value

Increase

Value

OFF/SET

Ignition Key

Turn On

System

4

1

8

2

0

OFF/SET

Preheat

Duration

4

8

2

1

OFF/SET

Input:

Time Seconds

1

2

8

4

4

0 Seconds

0~60 Seconds

(-) MAN

(+) AUTO

2

OFF/SET

Repeated

Starts

4

8

1

2

OFF/SET

Input: Number

Starts

4

8

1

2

1

3

0~15

(-) MAN

(+) AUTO

4

OFF/SET

Pause

Between Starts

4

8

2

1

OFF/SET

Input:

Time Seconds

4

8

2

1

5

5 Seconds

5~75 Seconds

(-) MAN

(+) AUTO

6

OFF/SET

Overcrank

8

2

4

1

OFF/SET

Input:

Time Seconds

8

2

4

1

2

10 Seconds

2~30 Seconds

(-) MAN

(+) AUTO

10

OFF/SET

Engine Cool-

Down Cycle

8

1

2

4

OFF/SET

Input:

Time Seconds

1

2

8

4

60

0 Seconds

0~900

Seconds

(-) MAN

(+) AUTO

Reference Table 12 when programming of the MSS-200

is required.

This manual is related to the following products: