MSS-200 DIAGNOSTICS (AUTO MODE)

Reference Table 13 for a brief explanation of the LED status

indicators when MSS-200 is in AUTO mode.

Table 13. MSS-200 LED Status Auto Mode

LED's

Description

1

2

4

8

Automatic self test. The MSS-200 is turned on. System is energized.

1

2

8

4

MSS-200 is awaiting start signal via ground (switch contact is open). Changing to manual start

mode is possible by pressing the OFF/SET and then the MAN button.

1

2

4

8

Switch contact was closed while energizing the system. Pushing the AUTO or OFF/SET then

MAN button will start engine.

8

2

4

1

Engine is preheating.

8

2

4

1

Engine is starting.

8

4

1

2

Engine is in repeated start mode.

8

4

1

2

Engine is running. The AUTO LED is lit indicating that the engine was started automatically by

grounding the AUTO terminal.

8

1

2

8

While the engine was running, the switch contact was closed or the OFF/SET button was pushed

one time. Engine is in the cooling down cycle.