OPERATION (MANUAL MODE)

Engine Shut-Down

1. Place engine throttle control in the idle position and

place the ignition key in the

OFF position.

Pump Inspection After Use

2. It is recommended that the pump be inspected after

each use for damage or wear.

3. Drain and flush pump volute and priming system from

suction end.

4. Inspect impeller for wear or damage and measure

impeller clearance if it appears worn. Inspect interval

should be about every 1000 hours. This inspection

should be done when the pump is scheduled for

maintenance inspection.

5. Inspect discharge check valve for wear or damage.

Replace if necessary.

6. Inspect fuel tank and check for water by removing 0.5-

inch drain plugs. Do not overtighten when replacing.

7. Check oil reservoirs for contamination or water.
8. Do dry vacuum test to check seal and check valve

seal. This check should be done when the pump is

scheduled for maintenance inspection.

CAUTION -Disconnecting Discharge Hose

If pumping in a positive head (pumping up hill), be

sure to open discharge check valve drain and release

pressure before uncoupling hose.

Pump Storage

For storage of the pump for over 30 days, the following is

required:

„

Drain the fuel tank completely.

„

Run the engine until the fuel in the injection system is

completely consumed.

„

Completely drain used oil from the engine crankcase

and fill with fresh clean oil, then follow the procedures

described in the engine manual for engine storage.

„

Remove the drain plug from the pump and drain out any

water from left in the housing.

„

Remove the pump cover and clean inside of pump

housing. Coat inside of pump housing with a light film

of oil to reduce corrosion. A spray can of oil works well

for this application.

„

Cover suction and discharge ports with duct tape to

prevent any foreign matter from falling into pump.

„

Cover pump and engine with plastic covering or

equivalent and store in a clean, dry place.