7 analog inputs, 1 overview, 8 digital inputs and outputs – Lenze 931K User Manual
Page 87: 2 description of the objects, Analog inputs, Overview, Digital inputs and outputs, Description of the objects, Parameter setting, Analog inputs overview
Parameter setting
Analog inputs
Overview
l
87
KHB 13.0002−EN 4.1
7.7
Analog inputs
7.7.1
Overview
The drive controller is provided with two analog inputs, which can be used, for instance, to
define setpoints. These analog inputs can only be parameterised via the Small Drive
Control program.
7.8
Digital inputs and outputs
7.8.1
Overview
All digital inputs of the drive controller can be read via the CAN bus and the two digital
outputs can be set as desired.
7.8.2
Description of the objects
Index
Name
Possible settings
Characteristics
Lenze
Selection
Description
60FD
h
0 digital_inputs
0
00000000
h
{1}
FFFFFFFF
h VAR
UINT32
RO
MAP
Reading−out of the digital
inputs.
Bit no.
Value
Digital input
0
00000001
h
Neg. limit switch
1
00000002
h
Pos. limit switch
3
00000008
h
Interlock
(controller or
power stage
enable is missing)
16 − 25
03FF0000
h
DIN0 ... DIN9
60FE
h
0 digital_outputs
ARR
UINT8
RO
Ċ
Reading−out of the digital
outputs.
1 digital_outputs_
data
0
00000000
h
{1
h
}
FFFFFFFF
h Ċ
UINT32
RW
MAP
Bit no.
Value
Digital output
Setting of the 2 outputs. The
activation can be delayed by
up to 1 ms. By reading back
index 60FE_00
h
you can
check when the outputs are
really set.
0
00000001
h
Brake
16
00010000
h
Ready for
operation
17, 18
00060000
h
DOUT1, DOUT2