Commissioning, Position control parameterising of the homing run – Lenze 931K User Manual
Page 65

Commissioning
Position control
Parameterising of the homing run
l
65
KHB 13.0002−EN 4.1
No. Description
Identi
fier
Control
field
Comma
nd code
Index
Subin
dex
Data 1 Data 2 Data 3 Data 4
Data
length
Low
byte
High
byte
1
State query (read)
Each change of the state must be
executed depending on the initial state.
After a state change you have to wait for
the state change being indicated in the
status word.
601
4
40
41
60
00
00
00
00
00
2
Control word: shut down
With the ’shut down’ command, the
state is adapted to
Ready_To_Switch_On.
601
6
2B
40
60
00
06
00
00
00
3
State query (read)
(Explanation see step 1)
601
4
40
41
60
00
00
00
00
00
4
Control word: switch on
With the switch on command, the state
is adapted to Switched_On.
601
6
2B
40
60
00
07
00
00
00
5
State query (read)
(Explanation see step 1)
601
4
40
41
60
00
00
00
00
00
6
Control word: enable operation
With the enable operation command,
the state is adapted to
Operation_Enable.
Voltage is now applied to the motor.
However, the homing run does not start
yet.
601
6
2B
40
60
00
0F
00
00
00
7
State query (read)
(Explanation see step 1)
601
4
40
41
60
00
00
00
00
00
8
Control word: Enable operation and
homing start
The enable operation and homing start
commands start the homing run.
601
6
2B
40
60
00
1F
00
00
00
9
State query (read)
At this point the homing run is
executed. Homing is completed when
bit 12 (homing attained) is set in the
status word.
601
4
40
41
60
00
00
00
00
00
10
Control word: disable voltage
This command switches off the drive
and sets it to the Switch_On_Disabled
state.
601
6
2B
40
60
00
00
00
00
00
Tab. 8
Execution of the homing run by means of the state machine