Appendix, Index table – Lenze 931K User Manual
Page 144

Appendix
Index table
l
144
KHB 13.0002−EN 4.1
Characteristics
Possible settings
Name
Index
Description
Selection
Lenze
6510
h
0 drive_data
REC
UINT8
RO
Ċ
Not used.
1 serial_number
Ċ
UINT32
RO
MAP
Reading−out of the serial
number.
2 drive_code
Ċ
UINT32
RO
MAP
Reading−out of the
identification.
10 enable_logic
2
0
{1}
2
Ċ
UINT16
RW
MAP
Setting of the power stage
enable
0
Digital inputs of power stage
enable + controller enable
1
Digital inputs of power stage
enable + controller enable +
RS232
2
Digital input of power stage
enable + controller enable +
CAN
11 limit_switch_
polarity
1
0
{1}
1
Ċ
INT16
RW
MAP
Setting of the limit switch
polarity. The value always
refers to both limit switches.
0
NC contact
1
NO contact
15 limit_switch_
deceleration
200000
0
{1 rpm/s}
200000
Ċ
INT32
RW
MAP
Setting of the deceleration
used for braking when the
limit switch is reached in
normal operation (limit
switch emergency stop
ramp).
A1 drive_type
Ċ
UINT32
RO
MAP
Reading−out of the device
type, see also index
1018_02
h
product_code.
A9 firmware_main_
version
Ċ
UINT32
RO
MAP
Reading−out the main
version number of the
firmware (product version).
AA firmware_custom_
version
Ċ
UINT32
RW
MAP
Reading−out of the version
number of the
customer−specific firmware