Appendix, Index table – Lenze 931K User Manual
Page 123

Appendix
Index table
l
123
KHB 13.0002−EN 4.1
Characteristics
Possible settings
Name
Index
Description
Selection
Lenze
100C
h
0 guard_time
0
0
{1 ms}
65535
VAR
UINT16
RW
Ċ
For activating the node
guarding monitoring
function, the maximum time
between two remote
requests from the master is
parameterised. The
controller calculates this
time from the product of
guard_time and
life_time_factor. Therefore it
is recommended to overwrite
the life_time_factor with 1
and to select the time
directly via the guard_time
in milliseconds.
100D
h
0 life_time_factor
0
0
1
VAR
UINT8
RW
Ċ
The life_time_factor should
be overwritten with 1 to
select the guard_time
directly.
1010
h
0 store_parameters
ARR
UINT8
RO
Ċ
Not used.
1 save_all_
parameters
00000001
h
00000000
h
{1
h
}
65766173
h
Ċ
UINT32
RW
Ċ
Acceptance of default
parameter set in application
parameter set.
00000000
h
Default parameter set is not
accepted.
65766173
h
Save
Default parameter set is
accepted.
1011
h
0 restore_parameters
ARR
UINT8
RO
Ċ
Query on the number of
possible objects.
1 restore_all_default
_parameters
00000001
h
00000000
h
{1
h
}
64616F6C
h
Ċ
UINT32
RW
Ċ
Loading of the default
parameter set, only possible
if the power stage is
deactivated.
The CAN communication
parameters (node no., baud
rate and operating mode)
remain unchanged.
64616F6C
h
Load
Loading of default parameter
set.
00000001
h
Read access: Reset to default
values.