2 description of the objects, Description of the objects, Parameter setting – Lenze 931K User Manual
Page 71

Parameter setting
Loading and saving of parameter sets
Description of the objects
l
71
KHB 13.0002−EN 4.1
7.1.2
Description of the objects
Index
Name
Possible settings
Characteristics
Lenze
Selection
Description
1010
h
0 store_parameters
ARR
UINT8
RO
Ċ
Not used.
1 save_all_
parameters
00000001
h
00000000
h
{1
h
}
65766173
h Ċ
UINT32
RW
Ċ
Acceptance of default
parameter set in application
parameter set.
00000000
h
Default parameter set is not
accepted.
65766173
h
Save
Default parameter set is
accepted.
1011
h
0 restore_parameters
ARR
UINT8
RO
Ċ
Query on the number of
possible objects.
1 restore_all_default
_parameters
00000001
h
00000000
h
{1
h
}
64616F6C
h Ċ
UINT32
RW
Ċ
Loading of the default
parameter set, only possible
if the power stage is
deactivated.
The CAN communication
parameters (node no., baud
rate and operating mode)
remain unchanged.
64616F6C
h
Load
Loading of default parameter
set.
00000001
h
Read access: Reset to default
values.