Safety engineering – Lenze E94AYAE SM301 User Manual
Page 53
Safety engineering
Safety functions
Integration into the application of the controller
l
53
EDS94AYAE EN 7.0
Status word SMI_dnState
Bit
Name
Meaning
0
STO
Safe torque off is active.
3
EC_STO
Error stop category 0 is active (Safe Torque Off).
4
EC_SS1
Error stop category 1 is active (Safe Stop 1).
5
EC_SS2
Error stop category 2 is active (Safe Stop 2).
8
SLS1 monitored
Safely limited speed 1 is activated and maintained.
9
SLS2 monitored
Safely limited speed 2 is activated and maintained.
(from SM301 V1.1)
10
SLS3 monitored
Safely limited speed 3 is activated and maintained.
(from SM301 V1.1)
11
SLS4 monitored
Safely limited speed 4 is activated and maintained.
(from SM301 V1.1)
12
SDIpos monitored
Safe positive direction (SDIpos) is activated and maintained.
(from SM301 V1.3)
13
SDIneg monitored
Safe negative direction (SDIneg) is activated and maintained.
(from SM301 V1.3)
14
Error active
SM301 safety module in error status (trouble or warning).
Unlisted bits are reserved for future extensions!
Status word SMI_dnIOState
Bit
Name
Meaning
0
SD−In1
Sensor input 1 in ON state.
1
SD−In2
Sensor input 2 in ON state.
2
SD−In3
Sensor input 3 in ON state.
3
SD−In4
Sensor input 4 in ON state.
5
AIS
Restart acknowledgement via terminal in ON state.
6
AIE
Error acknowledgement via terminal ON state.
8
PS_AIS
Restart acknowledgement via safety bus.
9
PS_AIE
Error acknowledgement via safety bus.
12
SD−Out1
Safe output 1 (feedback output) in ON state.
Unlisted bits are reserved for future extensions!
If communication to the standard device is interrupted, e.g. by switching off the standard
device, the safety module responds by means of the following actions:
ƒ
Error stop with STO is activated
ƒ
"Warning" error message is transmitted
ƒ
The "ME" LED is blinking
The required fault acknowledgement (AIE) is possible via terminal or safety bus. For further