Safety engineering, Appendix module error messages – Lenze E94AYAE SM301 User Manual
Page 135

Safety engineering
Appendix
Module error messages
l
135
EDS94AYAE EN 7.0
Error type/response/
Note
Description
Field
Error type/response/
Note
Description
Error number
Safety functions
97
0x61
SS1/SS2: Stopping time exceeded
(The drive has not reached zero speed within the stopping time.)
Warning/STO
98
0x62
SLS1: Nlim1 exceeded
(The drive has exceeded the limited speed.)
Warning/response can be
set
99
0x63
SLS2: Nlim2 exceeded
(The drive has exceeded the limited speed.)
Warning/response can be
set
100
0x64
SLS3: Nlim3 exceeded
(The drive has exceeded the limited speed.)
Warning/response can be
set
101
0x65
SLS4: Nlim4 exceeded
(The drive has exceeded the limited speed.)
Warning/response can be
set
102
0x66
SLS/SMS: Error stop not executed
(The drive has exceeded the limited speed or maximum speed and
has not stopped the drive safely. Following error to no. 0x62 or
0x69)
Warning/STO
103
0x67
SDIpos: Wrong direction of movement
Warning/response can be
set
104
0x68
SDIneg: Wrong direction of movement
105
0x69
SMS: Nmax exceeded
(The drive has exceeded the monitored maximum speed.)
Warning/response can be
set
106
0x6A
SOS: Tolerance limit exceeded
(The drive has exceeded a tolerance limit.)
Warning/STO
107
0x6B
No encoder system parameterised
(SMS, SLS1 or SS2 are tried to be executed without an encoder
being parameterised.)
Warning/STO
108
0x6C
CAS: Circulation time exceeded
Maximum time between release and feedback of the cascading
function has been exceeded.
Warning/STO
109 0x6D
CAS: Hardware or discrepancy error
The cascading output has not been switched off quickly enough
by the hardware or there is a discrepancy at the cascading input.
Warning/STO
110
0x6E
SS1/SS2: Speed ramp exceeded
Monitoring of the speed ramp is activated. When the stop
function SS1/SS2 is executed, the deceleration of the speed ramp
is monitored. When the monitoring limits are exceeded, an error is
reported.
Warning/STO
111
0x6F
SLI: Safely limited increment exceeded
The safely limited increment is monitored in the special operation
mode. The parameterised increment has been exceeded.
Warning/STO
Test functions − output
128
0x80
Stuck at High SD−Out1, channel A
(Short circuit (High))
Trouble/−
SD−Out1: OFF state
129
0x81
Stuck at Low SD−Out1, channel A
(Short circuit (Low))
130
0x82
Stuck at High SD−Out1, channel B
131
0x83
Stuck at Low SD−Out1, channel B