Safety engineering – Lenze E94AYAE SM301 User Manual
Page 134

Safety engineering
Appendix
Module error messages
l
134
EDS94AYAE EN 7.0
Error type/response/
Note
Description
Field
Error type/response/
Note
Description
Error number
PROFIsafe
64
0x40
F_Dest_Add does not equal F address
PROFIsafe parameter
setting/STO
No error status
65
0x41
F_Dest_Add = 0 or FFFFhex
66
0x42
F_Source_Add = 0 or FFFFhex
67
0x43
F_WD_Time is 0 msec
68
0x44
F_SIL exceeds technical SIL
69
0x45
F_CRC_Length error
70
0x46
F parameter version incorrect
71
0x47
PROFIsafe CRC1 error
72
0x48
reserved (PROFIsafe standard)
−
73
0x49
reserved (PROFIsafe standard)
−
74
0x4A
reserved (PROFIsafe standard)
−
Test functions
81
0x51
Error SD−Inx/CLx
(internal short circuit in one of the inputs)
Trouble/−
OFF state for all SD−In
82
0x52
Error SD−Inx/CLx
(internal short circuit in one of the inputs)
89
0x59
Short circuit SD−Out
93 0x5D
Error − internal disconnecting path
(internal error of the safe switch−off logic)
Trouble/STO
OFF state for all SD−In and
SD−Out
94
0x5E
Test pulse error − internal switch−off path
(internal error of the safe switch−off logic)
Trouble/STO