Safety engineering, Appendix module internal codes – Lenze E94AYAE SM301 User Manual
Page 122

Safety engineering
Appendix
Module internal codes
l
122
EDS94AYAE EN 7.0
Index:
Data type:
Name:
Parameter:
C15115
S-bus: Control data display
BITFIELD_32
9460
d
= 24F4
h
Display of safety bus control data after filtering via C15113
Value is bit coded:
Information
(From SM301 V1.2)
Bit 0 STO
Safe torque off
Bit 1 SS1
Safe stop 1
Bit 2 SS2
Safe stop 2
Bit 3 SLS1
Safely limited speed 1
Bit 4 SLS2
Safely limited speed 2
Bit 5 SLS3
Safely limited speed 3
Bit 6 SLS4
Safely limited speed 4
Bit 7 SDIpos
Safe positive direction
(From SM301 V1.3)
Bit 8 SDIneg
Safe negative direction
(From SM301 V1.3)
Bit 9 ES
Safe enable switch
Bit 10 Reserved
Bit 11 OMS
Safe operation mode selector
Bit 12 Reserved
...
Bit 15 Reserved
Bit 16 PS_AIS
Restart acknowledgement via safety bus
Bit 17 PS_AIE
Fault acknowledgement via safety bus
Bit 18 Reserved
...
Bit 22 Reserved
Bit 23 SSE
Emergency stop function
Bit 24 SD−Out1
Safe output
Bit 25 Reserved
...
Bit 31 Reserved
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15200
OMS: Stop function
UNSIGNED_8
9375
d
= 249F
h
Selection of the stop function in special operation
Selection list
(Lenze setting bold)
Information
0 STO
Safe torque off
1 SS1
Safe stop 1
2 SS2
Safe stop 2
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer
C15201
OMS: motion function
UNSIGNED_8
9374
d
= 249E
h
Selection of the motion function in special operation
Selection list
(Lenze setting bold)
Info
3 SLS1
Safely limited speed 1
(Lenze setting up to SM301 V1.3)
4 SLS2
Safely limited speed 2
(From SM301 V1.1)
5 SLS3
Safely limited speed 3
(From SM301 V1.1)
6 SLS4
Safely limited speed 4
(as of SM301 V1.1)
11 Free traversing
(Lenze setting from SM301 V1.4)
þ Read access } Write access o Controller inhibit o PLC-STOP o No transfer