Pneumatic down pressure, Temperature sensor option, Pneumatic down pressure -5 – Kinze 4900 Front Folding Planter Rev. 5/14 User Manual
Page 63: Temperature sensor option -5

TM
Model 4900
M0247-01
Rev. 5/14
3-5
Row Unit Operation
PNEUMATIC DOWN PRESSURE
Row unit down pressure can be adjusted on-the-go as field conditions change. ISOBUS monitor adjusts pressure
(Older models may have a digital readout). One planter-mounted 12 VDC air compressor with 3-gallon capacity air
tank supplies air for the down pressure system.
Row Unit Air Spring
Packages include upper and lower air spring mounting castings for pull row units, 150 psi rated air springs, ⅜" O.D.
nylon hoses, dual solenoid air valve and stainless steel, 160 psi, 2" liquid-filled gauge and planter wiring harness.
NOTE: Assist springs are available through your Kinze dealer if additional down pressure is needed.
TEMPERATURE SENSOR OPTION
A ground temperature sensor option is available on
ISOBUS equipped planters.
The sensor should be installed on the following rows,
depending on your row size:
12 Row - Row 6
16 Row - Row 8
24 Row - Row 12
The sensor must be adjusted up or down until it is 5/8"
above seed tube opening.
Refer to IS842 for additional installation information.
Temperature
sensor with
cable
Seed tube
.625"