beautypg.com

Brother HL-1260 User Manual

Page 298

background image

CHAPTER 4 CONTROL PANEL

4–19

Display Message Parameters Settings

BaudRate= 9600

Baud rate
(Data transfer speed)

150, 300, 600, 1200, 2400, 4800,
9600, 19200, 38400, 57600, 115200
baud

CodeType=8 bits

Code type
(Data length)

7 bits or 8 bits

Parity =NONE

Parity
(Data error check)

None, even, or odd

Stop Bit=1 bits

Stop bits
(Data separator)

1 or 2

Xon/Xoff=ON

Xon/Xoff
(Handshake protocol)

ON:

DTR & Xon/Xoff handshake

OFF: DTR handshake only

DTR(ER) =ON

(Effective when

Xon/Xoff=ON)

Data terminal ready
(ER)

ON:

Makes DTR (ER) low when
the buffer is full.

OFF: Does not make DTR (ER)

low when the buffer is full.
DTR(ER) goes low only
when the printer is off-line.

Robust Xon =OFF

(Effective when

Xon/Xoff=ON)

Robust Xon ON: Sends Xon while waiting.

OFF: Sends Xon once, when the

printer status changes from
off-line to on-line.

■ Optional Interface

If you have installed a commercial modular input/output (MIO) card in the
printer, you can select the optional MIO interface in this mode. If the
installed MIO card requires any optional interface settings, they appear
under this menu. Set them, referring to the manual of the MIO card.

I/F=OPTION

Note
This setting appears only when the MIO card has been installed. For
installation of the MIO card, see

“MODULAR I/O CARD” in Chapter 5

.