1.10 Scanner Unit

(1) Unplug the LD PCB harness (scanner flat cable) connector (6P), and polygon harness (5P).

(2) Remove the beam from the body by loosening the screws.

(3) Remove the scanner unit from the body by loosening the screws.

Caution:

Do not disassemble the scanner unit, it can be only adjusted at the factory.

Left side

Rear

Figure 4.10

Right side

Front

Scanner mount plate

Cartridge stopper assy

C

B

A

Figure 4.9

Cartridge stopper assy

Scanner mount plate

Ground leaf spring

Screws

1.11 Cartridge Stopper Assy

(1) Loosen 4 screws and remove the scanner mount plate in the direction of the arrow (the

ground leaf spring is also released at the same time.)

(2) Release the hook by bending the arm of the cartridge stopper assy ( A ), slide the

cartridge stopper assy to the left ( B ) and the remove the cartridge stopper assy ( C ).

Figure 4.8

Polygon harness 5P

Screws

Screws

Beam

Scanner unit

Scanner flat cable 6P