Install Redundant Power Supply

The ERn redundant power supply (ERn-RPS) is an additional rack power supply that

powers the ERn enclosure if the primary rack power supply fails.

Status Indicator

When the redundant power supply is installed properly, and power is applied to the ERn

enclosure, the LED will indicate in green if the supply is powered. If the LED is off but the

primary rack supply status indicator is on, the redundant power supply requires servicing.

Alternatively, if the primary rack supply status LED is off, but the redundant power supply

is on, the primary rack supply requires service. Contact ETC Technical Services for

assistance.

See “Contacting ETC” on page 4.

N o t e :

The redundant power supply (ERn-RPS) is not supported in ERn4 enclosures at

230 VAC. Instead the ERn4 at 230 VAC is shipped from the factory with a rack

power supply installed in the top (normal) position and in the lower option module

slot as standard.

Install the redundant rack power supply in the bottom option

module slot of the ERn enclosure and secure it in place with the

two captured screws.