Install a Paradigm Repeater or Dual Repeater Module

The Paradigm station repeater (P-REP) module extends the system station bus length by

1,640 feet (500m) and adds support for up to 30 additional stations.

The Paradigm dual station repeater (P-DREP) module extends the system station bus

length 3,280 feet (1,000m) through two separate topology-free Echelon segments (each

supporting 1,640 feet (500m) of additional LinkPower station wire each) and adds support

for up to 30 additional stations.

Both repeater module types may only be utilized in the top module slots of the ERn4

enclosure.

The following table lists the recommended control wire types used in a typical Unison

installation and the maximum wire runs allowed.

Purpose

Link Power

(Belden 8471)

DMX (Belden

9729)

Ethernet

(Cat5 /Belden

1583a)

Feet

Meter

Feet

Meter

Feet

Meter

Total length of control wire
(without repeater module)

1640

500

1600

487

328

100

Maximum wire length (ERn
to station)

1313

400

1600

487

N/A

N/A

Maximum repeater distance

1640

500

N/A N/A

N/A

N/A