Rack Mounting Specifications

An ERn configured for installation in a 19” equipment rack requires 5U of rack space for an

ERn2 and 9U of rack space for an ERn4. ERn enclosures are provided with rack mounting

brackets attached to the ERn enclosure at shipment. The locking door attaches to the

equipment rack for a secure installation.

Dimensions and Weights

Installation Environment Requirements

For your safety, you should install a circuit breaker cabinet or other readily accessible
input power disconnect device in the same area as the Unison ERn enclosure.
Breakers not in the same room must have a physical means to be locked off.

A clean (not dusty), temperature controlled environment with the following conditions:

ambient temperature of 32-104°F / 0-40°C

ambient humidity of 10-90%, non-condensing

Restricted public access to prevent tampering.

All CE equipment is tested to EMC category B environment.

Enclosure
Type

Height

Width

Depth

Product

Weight

Shipping

Weight

inches

mm

inches

mm

inches

mm

lbs

kgs

lbs

kgs

ERn2-RM w/
rack door

8.8

223

19

483

9.6

244

16.6

7.7

20

9.1

ERn4-RM w/
rack door

14.1

358

19

483

9.6

244

23.8

11

25

11.3

C A U T I O N :

HVAC systems must at all times maintain the specified ambient temperature at the