ElmoMC SimplIQ Software Manual User Manual
Page 211

SimplIQ
Software Manual
13BFilters
MAN-SIMSW (Ver. 1.4)
14-2
Filter Parameters
Maximum
Order
Speed controller high-order filter
KV[0]…KV[47]
Position controller high-order filter
KV[48]…KV[75]
Analog position sensor filter
KV[76]…KV[87]
Order 4 (2 blocks)
Analog reference to speed controller
KV[88]…KV[99]
Order 4 (2 blocks
Table
14-1: KV[N] Filter Parameters
The high-order filter parameters of the speed controller are as follows:
Parameter Description
Value
Range
KV[0]
Is filter active?
0: Filter not active and bypassed. All
other filter parameters ignored.
100: Filter is active.
KV[1]
Last index in KV[N] used
for this filter
1+5n, where 1 ≤ n ≤ 9 is the number
of used second-order links. The
maximum resulting filter order is 18.
KV[2]…KV[6]
Parameters of first link
KV[7]…KV[11]
Parameters of second link
KV[12]…KV[16]
Parameters of third link
KV[17]…KV[21]
Parameters of fourth link
KV[22]…KV[26]
Parameters of fifth link
KV[27]…KV[31]
Parameters of sixth link
KV[32]…KV[36]
Parameters of seventh link
KV[37]…KV[41] Parameters of eighth link
KV[42]…KV[47]
Parameters of ninth link
Table
14-2: Speed Controller High-order Filter Parameters
The high-order filter parameters of the position controller are as follows:
Parameter Description
Value
Range
KV[48]
Is filter active?
0: Filter not active and bypassed. All
other filter parameters ignored.
100: Filter is active.
KV[49]
Last index in KV[N] used
for this filter
49+5n, where 1 ≤ n ≤ 5 is the number
of used second-order links. The
maximum resulting filter order is 10.
KV[50]…KV[54]
Parameters of first link
KV[55]…KV[59]
Parameters of second link
KV[60]…KV[64]
Parameters of third link