3-3

3.4

Errors and Exceptions in RS-232

If an error is intercepted (over-run, noise, parity or framing), the entire message,
including the error, is discarded and a “communication error” code response is
transmitted.

The communication is defined as 8 bits per character. The

SimplIQ

drive will normally

only transmit characters in the range [0…127] with the exception of error codes (refer to

section

3.1

). The

SimplIQ

drive accepts RS-232 bytes only in the range [0…127]; received

byte values in the range [128…255] are treated as UART errors.

Empty strings with terminators are echoed back, but are otherwise ignored.