2 periodic query, 3 automatic routines, Periodic query -4 – ElmoMC SimplIQ Software Manual User Manual

Page 189: Automatic routines -4

background image

SimplIQ

Software Manual

Sensors, I/O and Events

MAN-SIMSW (Ver. 1.4)

12-4

12.4.2 Periodic Query

This is possible only in CAN networks. The user can map the digital input word to a
synchronous PDO. The host can collect the input state of multiple slaves as a response to
a single sync. The following table summarizes some of the periodical query properties.

Topic Comment

Capture probability

Low. An input pulse may slip away unnoticed between
consecutive syncs.

Deterministic delay

Yes. 0.5 milliseconds maximum + CAN network time.

Use

CAN networks only. Host logics only.

Table

12-3: Periodic Query Properties

12.4.3 Automatic Routines

Many events can be tied to automatic handler routines in the user program. For more
information about automatic user program routines, refer to

section

5.8.9

. The following

table summarizes some of the automatic routine properties.

Topic Comment

Capture probability

High. An input pulse may slip away unnoticed only if the user
program is not running, the input is masked or the pulse is so
short that it does not pass through the input filters.

Deterministic delay

No, although in most cases, the automatic routine will start
within 2 milliseconds.

Use

User program logic.

Table

12-4: Automatic Routine Properties

12.4.4 Real Time: Motion Management, Homing, Capture

and

Flag

The following can be real-time responses to events:
ƒ

The motor can stop, or a move in one direction can be prevented (refer to

section

11.3

and

Chapter 10:

).

ƒ

A new motion can begin (refer to the BG command section of the

SimplIQ

Command

Reference Manual and

Chapter 10:

of this manual).

ƒ

The power amplifier can be disabled.

ƒ

The position counters can be logged.

ƒ

The value of the position counter can be modified, and the position counter may stop.

ƒ

An output connector pin can be flagged.