4.2

A-1

AppenDix A

Fm aPPROvaL DESCRIPTION

Class I, Div. 1, Groups B, C & D T5;

Class I, Div. 2, Groups B, C & D T4;

Class I, Zone 1/2 AEx d IIC T5;

Class II/III, Div. 1/2, Groups E, F & G.

Tamb –40°C to +75°C

NEMA/Type 4x, IP66

Conduit seal not required.

Performance verified in accordance with:

ANSI/ISA-92.00.01

ANSI/ISA-12.13.01 (CGS excluded)

FM 6310/6320

ANSI/ISA-12.13.04/FM 6325

This approval does not include or imply approval of gas detector heads or other apparatus to which the subject

instrument may be connected. In order to maintain a Factory Mutual Research approved system, the measurement

input signal to which this instrument is connected must also be approved by Factory Mutual Research.

noTe

Consideration must be given to overall Gas System Performance Requirements.

WarnIng

When a sensor/detector is connected directly to the UD10 housing, the lower ratings of the two devices

will prevail.