SECTION 9 RECOMMENDED SERVICE PARTS STOCK
30/35/40/45 electric Lifts
The following list will service fleets of machines (built to current production per date on the front cover) with
emergency repair parts which can be installed in the field. Parts from the list should be replaced when inven-
tory is depleted to keep service parts stock supplied. For further information, contact your JLG dealer or the
JLG Industries Parts Department.
JLG PART
NUMBER
DESCRIPTION
QTY PER FLEET
1-4
5-9
10 OR MORE
STANDARD PARTS
3990053
Sensor, Tach (Figure 1-3)
1
1
1
2400045
Fuse (Figures 1-7 and 7-7)
2
2
2
4360372
Sensor, Level (Figure 1-7)
1
1
1
2120072
Element, Hydraulic Filter (Figure 1-12)
4
8
12
7013709
Breather/ Dipstick Assembly (Figure 1-12)
1
2
3
7010538
Coil (Figures 1-12, 2-1 and 2-4)
1
1
1
4360474
Switch, Key (Figures 2-10 and 2-11)
1
1
1
2860030
Key, Replacement (Figures 2-10 and 2-11)
1
1
1
4360475
Switch, Emergency Stop (Figures 2-10, 2-11 and 4-4)
1
1
1
4360314
Switch, Toggle (Figures 2-10, 2-11 and 4-4)
1
1
1
4360069
Breaker, Circuit - 10 Amp (Figures 2-11 and 4-4)
1
1
1
4360476
Contact Block (Figures 2-11 and 4-4)
1
1
1
4360031
Footswitch (Figure 4-1 and 4-2)
1
1
1
4360445
Potentiometer (Figure 4-4)
1
1
1
4360328
Switch, Toggle (Figure 4-4)
1
1
1
4360274
Switch, Push Button (Figure 4-4)
1
1
1
4360112
Breaker, Circuit - 5 Amp (Figure 4-4)
1
1
1
3740087
Relay (Figures 4-4, 7-1 and 7-2)
1
1
1
1600175
Controller (Figure 4-4)
1
1
1
7011942
Electrical Assembly - 1600175 Controller (Figure 4-5)
1
1
1
7003789
Switch, Steer - 1600175 Controller (Figure 4-5)
1
1
1
3990001
Diode - 3.5Amp (Figure 7-7)
2
2
2
3990010
Diode - 6 Amp (Figure 7-7)
2
2
2
2400041
Fuse (Figure 7-7)
2
2
2
7013314
PC Board (Figure 7-7)
1
1
1
7013315
Resistor/Bracket Assembly (Figure 7-7)
1
1
1
VARIABLE PARTS
7011593
Fuse (Machines with 110V Battery) (Figure 1-8)
2
2
2
7011645
Fuse (Machines with 110V Battery) (Figure 1-8)
2
2
2
7018569
Fuse (Machines with 220V/60Hz Battery) (Figure 1-8)
2
2
2
7011593
Fuse (Machines with 220V/50Hz Battery) (Figure 1-8)
2
2
2
7011508
Fuse (Machines with 220V/50Hz Battery) (Figure 1-8)
2
2
2
7018570
Fuse (Machines with 110-220V/50Hz Battery) (Figure 1-10)
2
2
2
4360321
Switch, Limit (Figures 3-1, 3-2 and 3-4)
1
1
1
7013310-30E
Module, Sevcon Control (30electric) (Figure 7-7)
1
1
1
7013310-35E
Module, Sevcon Control (35electric) (Figure 7-7)
1
1
1
7013310-40E
Module, Sevcon Control (40electric) (Figure 7-7)
1
1
1
7013311
Module, Sevcon Control (45electric) (Figure 7-7)