Local Management Session

You establish a local management session with the AT-LX3800U chassis
when you use the management cable included with the chassis to connect
a terminal or PC with a terminal emulation program to the RS-232 port on
the chassis. The RS-232 port is located on the front panel of the
AT-LX3800U chassis and has a DIN-8 style connector.

This type of management session is referred to as “local” because you
must be physically close to the chassis, such as in the wiring closet where
the chassis is located.

After the session starts, the menus are displayed from which you can
make selections to configure and manage the chassis. You can configure
all of the chassis operating parameters from a local management session.

A chassis does not need an Internet Protocol (IP) address for you to
manage it locally. You can start a local management session on the
chassis at any time and not interfere with the chassis operations.

Starting a Local

Management

Session

To start a local management session on the chassis, perform the following
procedure:

1. Connect the DIN-8 end of the management cable included with the

AT-LX3800U chassis to the RS-232 terminal port on the front of the
chassis, as shown in Figure 1.

Figure 1. Connecting the Management Cable to the RS-232 Port

2. Connect the other end of the cable to an RS-232 port on a terminal or

PC with a terminal emulation program.

3. Configure the terminal or terminal emulation program to the following

settings: