Enabling factory default reset – Allied Telesis AT-GS950/24 User Manual
Page 362
Chapter 29: Rebooting the AT-GS950/24
362
remain Enabled on both the switch management software and the
physical front panel ecoFriendly button.
8. Click Accept on the message.
The Factory Default Reset page changes and displays the Factory
Default Reset feature as Disabled. See Figure 150.
Figure 150. Factory Default Reset Disabled Page
9. From the main menu on the left side of the page, select Save Settings
to Flash to permanently save your changes.
Enabling Factory
Default Reset
If the Factory Default Reset feature is disabled, and you choose to
Enable it, perform the following procedure:
1. From the main menu on the left side of the page, select the Tools
folder.
The Tools folder expands.
2. From the Tools folder, select Reboot.
The Factory Default Reset/Reboot Page is displayed. See Figure 150.
3. Go to the Factory Default Reset section on the upper part of the page.
The Factory Default Reset field should be set to Disable.
Note
If the Factory Default Reset field is already set to Enable, you do
not need to continue with this procedure.
4. To enable the factory default reset feature, select Enable on the pull-
down menu of the Factory Default Reset field.
The Factory Default Reset/Reboot Page changes to include a
Password field for entering a password. See Figure 151 on page 363.