Figure 107. rmon event configuration example – Allied Telesis AT-GS950/24 User Manual

Page 265

background image

AT-GS950/24 Web Interface User Guide

265

Community: This parameter specifies the community where you
want to send the SNMP trap.

Owner: This parameter is used to identify the person who created
an entry. It is primarily intended for switches that are managed by
more than one person and is an optional field.

4. Once you have configured the parameters, click Add.

Your entry appears in the table at the bottom of the page. See Figure
107
.

Figure 107. RMON Event Configuration Example

5. If you want to configure additional RMON events, repeat Step 3 and

Step 4.

6. From the main menu on the left side of the page, select Save Settings

to Flash to permanently save your changes.