NORMAL OPERATING MODE

When the MDC is powered up, it is in the Normal Operating

Mode with the Indication Display Module viewed. The up and

down arrow keys are used to scroll through the Indication

Displays. The Indication Displays are referenced as 1 to 4 with

the factory default settings of 1 (SPEED), 2 (OPERATING

STATUS), 3 (ALARM STATUS), and 4 (TRIM). The Indication

Displays can be programmed to show other parameters and

automatically scroll if desired (See Program Displays Menu for

details). All Dedicated Function Inputs, User Inputs, and Alarm

Outputs are operational in the Normal Operating Mode.

From the Normal Operating Mode, two other modules may be

entered. The SET key enters the User Setpoints Module and the

PGM key enters the Programming Module. The last display

viewed when exiting the Indication Display Module will be the

first display viewed upon return. Also, the last Indication Display

viewed at power down, will be the one viewed on power up.

The User Setpoints Module may be accessed from any of the

Indication Displays or from the Programming Module (with the

exception of the Operating Mode Selection Menu). The

Setpoints Module is used to set all of the user setpoints, such as

speed, alarm, and gain values (see Programming User

Setpoints). User Setpoints may be edited while the MDC is in a

RUN or JOG mode.

The flowchart at right shows the three main Modules that are

accessible in the Normal Operating Mode.

-8-