beautypg.com

Appendix “b” - specifications & dimensions – Red Lion GEMINI 42 User Manual

Page 48

background image

APPENDIX “B” - SPECIFICATIONS & DIMENSIONS

1. DISPLAY: 6-digit 0.56" (14.2 mm) High LED display.

2. POWER REQUIREMENTS:

AC Versions

AC Power: Switch selectable 115/230 VAC (±10%), 50/60 Hz, 20 VA

DC Power: 11 to 14 VDC @ 0.7 amp maximum

3. SENSOR POWER: +12 VDC (±25%) @ 100 mA.

4. MEMORY: Non-volatile E

2

PROM memory retains all programming

information and count values (except Counter Load values) when power is

removed or interrupted.

Power Cycles (ON/OFF): 100,000 minimum

Data Retention: 10 yrs. minimum

5. INPUTS 1 AND 2: Switch selectable to accept count pulses from a variety of

sources including switch contacts, outputs from CMOS or TTL circuits, and

all standard RLC sensors.

Current Sourcing - Unit provides pull-down resistor for sensor with current

sourcing outputs. (Max. input voltage = 28 VDC @ 7 mA.)

Current Sinking - Unit provides pull-up resistor for sensors with current

sinking outputs. (Max. sensor current = 1.6 mA.)

Debounce - Damping capacitor provided for switch contact debounce. Limits

count speed to 100 Hz maximum and input pulse widths to 5 msec. minimum.

Lo Bias - Input trigger levels V

IL

= 1.5 V, V

IH

= 3.75 V

-46-

Hi Bias - Input trigger levels V

IL

= 5.5 V, V

IH

= 7.5 V

Note: Bias levels given are ±10% @ 12 VDC. They vary proportionally with

sensor supply voltage at “DC OUT” terminal.

6. MAGNETIC PICKUP INPUT:

Sensitivity: 150 mV peak (typical @ 12 VDC)

Hysteresis: 100 mV

Input impedance: 26.5 KΩ @ 60 Hz

Maximum Input Voltage: ±50 Vp

7. RATE ACCURACY AND REPEATABILITY: +0.012%

8. RATE MINIMUM INPUT FREQUENCY: 0.03 Hz

Note: At frequencies below 0.03 Hz (1 pulse every 32 sec.) the rate display will

go to zero.

9. CONTROL INPUTS:

Reset - Active low (V

IL

= 1.5 V max.), internally pulled up to +12 VDC (I

SNK

= 3

mA), activation and de-activation response time = 10 msec.

Program Disable - Active low (V

IL

= 1.5 V max.), internally pulled up to +5

VDC (I

SNK

= 1 mA).

Print Request - (Serial Communications) Active low, (V

IL

= 1.5 V max.),

internally pulled up to +5 VDC (I

SNK

= 1 mA).

10. MAXIMUM COUNT RATES:

NOTE: Mounted units require a clearance of 6.8" (W) behind the panel.

DIMENSIONS In inches (mm)

COUNTER/RATE MODE [41 1]

MODE

X1

X2

X4

Uni or Bi-directional

10 KHz

5 KHz

Anti-Coincidence Add/Subtract

4 KHz

2.5 KHz

Separate Input

8 KHz

4 KHz

Quadrature

5 KHz

4.5 KHz

2.5 KHz

This manual is related to the following products: