CODE 64 - COUNTER A SCALE MULTIPLIER

There are four Counter A scale multipliers that are available. They effectively

divide the internal Counter A Value by 1, 10, 100, and 1000 respectively, to yield

the displayed Counter A Value. Note: Use of a small scale multiplier in

conjunction with a small Scale Factor could cause the internal Counter A Value

to be exceeded before the 6-digit display value is exceeded.

[64 1] x1

[64 2] x0.1

[64 3] x0.01

[64 4] x0.001

CODE 65 - COUNTER A DECIMAL POINT & LEADING ZERO

BLANKING

There are six basic modes of decimal point placement for Counter A of the

Gemini. The decimal point is placed to the right of the display digit that

corresponds to the mode identifier. (The right most decimal point, digit 1, is

never turned on.) A “-” sign in front of the mode identifier will inhibit leading

zero blanking. The absence of a “-” sign will enable leading zero blanking.

[65 1]

0

[65 2]

0.0

[65 3]

0.0 0

LEADING ZERO

[65 4]

0.0 0 0

BLANKING

[65 5]

0.0 0 0 0

[65 6] 0.0 0 0 0 0

[65-1]

0 0 0 0 0 0

[65-2]

0 0 0 0 0.0

[65-3]

0 0 0 0.0 0

LEADING ZERO

[65-4]

0 0 0.0 0 0

BLANKING INHIBITED

[65-5]

0 0.0 0 0 0

[65-6]

0.0 0 0 0 0

CODE 66 - “OPERATOR ACCESSIBLE FUNCTIONS” MODES

The Gemini has six basic levels of “Operator Accessible Functions”. Each of

these levels can be modified to enable or disable manual reset. When the “PGM.

DIS.” (program disable) terminal is connected to “COMMON”, access to all

functions is disabled except for those listed below which will remain enabled. All

of the function codes and parameters can be interrogated, regardless of the

“Operator Accessible Functions” mode selected.

A “-” sign in front of the mode identifier will disable the front panel Reset

button and the “RST.” terminal.
Note: The front panel reset button can be independently disabled by using the

disable reset DIP switch.

[66 1] NO FUNCTIONS ENABLED EXCEPT RESET - In this mode, manual

reset is enabled, but none of the programming functions can be changed.

[66 2] PRESET PROGRAMMING AND RESET ENABLED - In this mode,

manual reset and the programming of the Preset Values are enabled.

[66 3] SCALE FACTOR PROGRAMMING AND RESET ENABLED - In this

mode, manual reset and the programming of the Scale Factor Values are enabled.

[66 4] SCALE FACTOR, PRESET PROGRAMMING AND RESET

ENABLED In this mode, manual reset and the programming of the Scale

Factor and Preset Values are enabled.

[66 5] PRESET, COUNTER LOAD PROGRAMMING, AND RESET

ENABLED - In this mode, manual reset and the programming of the Presets

and Counter Load Values are enabled.

[66 6] PRESET, SCALE FACTOR, COUNTER LOAD PROGRAMMING,

AND RESET ENABLED - In this mode, manual reset and the programming of

the Preset, Scale Factor and Counter Load Values are enabled.

[66 -1]

[66 -2]

[66 -3]

These modes are the same as above with

[66 -4]

the exception that reset is disabled.

[66 -5]

[66 -6]

-26-