beautypg.com

Port symbolic name, Port states, Port operational states – HP 8.20q Fibre Channel Switch User Manual

Page 98: Table 21 port operational states, 21 port operational states, Port symbolic, Name

background image

98

Port symbolic name

To change the symbolic name of a port:

1.

Open the faceplate display and select a port.

2.

Select Port > Port Properties to open the Port Properties dialog box.

3.

Click inside the Symbolic Name field and enter a new name for the port.

4.

Click OK.

Port states

The port operational state refers to the actual port state and not to the administrative state you may have

assigned. The port administrative state refers to the user-requested state. For more information, see

Port

operational states

” (page 98). Port administrative states have two forms: the configured administrative state

and the current administrative state. For more information, see

Port administrative states

” (page 99).

Port operational states

To view the operational state of each port in the faceplate display, open the View menu and select View

Port States.

Table 21

lists the possible operational states and descriptions.

Configured Type

The port type saved in the switch configuration. To change, click in the

field and select an option from the drop-down list.

I/O Stream Guard

The I/O Stream Guard option suppresses the Registered State Change

Notification (RSCN) messages on a port basis. I/O Stream Guard should

be enabled only on ports connected to initiator devices. To change, click

in the field and select an option from the drop-down list. The options are:

Enable–Suppresses the reception of RSCN messages from ports for

which I/O Stream Guard is enabled.

Disable–Enables free transmission and reception of RSCN messages.

Auto–Suppresses the reception of RSCN messages when the port is

connected to an initiator device with an HBA. The default is Auto.

Device Scan

The Device Scan feature queries the connected device during login for

FC-4 descriptor information. Disable this option only if the scan creates a

conflict with the connected device.

Table 20

Port Properties dialog box fields (Continued)

State

Description

Table 21

Port operational states

State

Description
Online—Port is active and ready to send data.

None

Inactive—Port operational state is offline, but administrative state is online.
Isolated—E_Port has lost its connection. See

Table 18

for information

about why the E_Port is isolated.

Offline—Port is active, can receive signal, but cannot accept a device

login.

Diagnostics—Port is in diagnostics mode in preparation for testing.

Downed—The port is disabled, power is removed from the lasers, and the

port cannot be logged in.

This manual is related to the following products: