NOTE:

Disabling the Merge Auto Save parameter can be useful to prevent the propagation of zoning

information when experimenting with different zoning schemes. However, leaving the Merge Auto Save

parameter disabled can disrupt device configurations should a switch have to be reset. For this reason, the

Merge Auto Save parameter should be enabled in a production environment.

Default Zone

The Default Zone parameter enables (Allow) or disables (Deny) communication among ports/devices that

are not defined in the active zone set or when there is no active zone set. This parameter must have the

same value throughout the fabric. However, the Default Zone parameter is not automatically distributed

throughout the fabric and must be configured to the same state in every switch in the fabric.

Discard Inactive

The Discard Inactive parameter automatically removes inactive zones and zone sets when a zone set is

activated or deactivated from a remote switch.

Saving and restoring the zoning database to a file

You can save the zoning database to an XML file, restore the saved database or the default zoning (which

clears the switch of all definitions). You can also remove all zones and zone set definitions.

Saving the zoning database to a file

To save a zoning database to an XML file:

1.

Select Zoning > Edit Zoning.

2.

In the Edit Zoning dialog box, select File > Save As.

3.

In the Save dialog box, enter a file name for the database file.

4.

Click Save to save the zoning file.

Restoring the zoning database from a file

To restore the zoning database from an XML file:

CAUTION:

Restoring the zoning database from a file will replace the current zoning database on the

switch.

1.

Select Zoning > Edit Zoning to open the Edit Zoning window.

2.

Select File > Open File.

A popup window prompts you to select an XML zoning database file.

3.

Select a file and then click Open.

Restoring the default zoning database

Restoring the default zoning clears the switch of all zoning definitions.

NOTE:

This command will deactivate the active zone set.

To restore the default zoning database:

1.

Select Zoning > Restore Default Zoning.

2.

Click OK to confirm that you want to restore default zoning and save changes to the zoning database.