Removing the System Reporter Components
3PAR System Reporter User’s Guide
System Reporter 2.8
3.12 Removing the System Reporter Components
This section describes how to remove the 3PAR System Reporter Components. This includes
removing the System Reporter sampler and default database, as well as deleting the optional
MySQL database (when applicable).
3.12.1 Removing the System Reporter Tools on Windows
To remove the System Reporter tools on WIndows:
1
Go to the Windows Control Panel, open Administrative Tools and then Services.
2
In the Services window, right-click 3PAR System Reporter sampler and then click
Stop. Close the Services window.
3
From a command prompt, change to the directory where you installed the 3PAR System
Reporter tools:
4
Execute the following command:
5
Exit and close the command prompt window.
6
Using Windows Explorer, go to the location where you installed the 3PAR System
Reporter tools (for example,
C:\Program Files\3par\System Reporter
) and delete
the entire directory.
7
Locate and remove the
inservstats.db
file if the file was in a location other than the
System Reporter folder. Also remove the file
inservstats.db-journal
if present in the
same folder.
8
(Optional). In the location where you installed Apache HTTP Server, locate the
htdocs
directory (for example,
C:\Program Files\Apache Group\Apache2\htdocs
) and
delete the
3par
subdirectory (
C:\Program Files\Apache
Group\Apache2\htdocs\3par)
.
# cd \program files\3par\system reporter
# winserv uninstall "3PAR System Reporter sampler”