7 limit count, 8 condition, 9 condition value – HP 3PAR System Reporter Software User Manual
Page 185: 10 recipient, 5 example of an alert rule, Limit count, Condition, Condition value, Recipient, Example of an alert rule

7.17
Configuring Rules for Email Alerts
System Reporter 2.8
3PAR System Reporter User’s Guide
7.4.4.7 Limit Count
The alert will only be generated if the number of objects for which the Metric exceeds the
Limit Value (in the direction specified by Direction) is greater than Limit Count in any given
sample. This should be an integer.
7.4.4.8 Condition
Specifies the condition (min_read_iops, min_write_iops, min_total_iops) that should be
monitored.
7.4.4.9 Condition Value
Specifies the condition value.
7.4.4.10 Recipient
Email address to which the alert email should be sent.
7.4.5 Example of an Alert Rule
shows an example of a configured alert. In this example, System Reporter will send
an email alert to email@address each time it inserts a high-resolution sample in which more
than 0 (Limit Count) VLUNs (including VLUNs in all systems) has a total (reads and writes
included) average service time in millisecs of greater than (>) 1000 (Limit Value).
Figure 7-3. Example of an alert rule
An example of the email alert is shown
Figure 7-4. Example of an alert email