4 the alertconfig table, The alertconfig table – HP 3PAR System Reporter Software User Manual
Page 297
10.5
Administrative Tables
System Reporter 2.8
3PAR System Reporter User’s Guide
10.3.4 The alertconfig Table
The alertconfig_2 table contains a row for each alert configuration rule.
Table 10-4. alertconfig_2 Table
Column
Type
Comment
alertid
INTEGER PRIMARY
KEY
(AUTO_INCREMENT)
A unique identifier for each rule.
data_table
VARCHAR(32) NOT
NULL
The data table on which the rule operates.
Currently supported values are:
statport
statport_nodesum
statport_syssum
statpd, statpd_nl7
stapd_fc10
statpd_fc15
statpd_ssd150
statpd_sum
statpd_nl7sum
statpd_fc10sum
statpd_fc15sum
statpd_ssd150sum
statld
statvlun
statcpu
resolution
VARCHAR(32) NOT
NULL
The sample resolution, one of hires,
hourly or daily.
inserv
VARCHAR(32) NOT
NULL
The InServ system name that the alert rule
is applied to. If this is the empty string
(blank) then the alert rule is applied to all
InServ systems. If this is not the empty
string, it should match one of the values in
the name column of the system_3 table.
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (93 pages)
- Data Protector Express Basic-Software (83 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)