HP 3PAR System Reporter Software User Manual
Page 323

10.31
The Sample Data and Inventory Tables
System Reporter 2.8
3PAR System Reporter User’s Guide
d_qlen
DOUBLE PRECISION NOT
NULL
Difference between qlen value from last
sample for the same object.
busy
DOUBLE PRECISION NOT
NULL
Time in microsecs that the device has been
busy.
d_busy
DOUBLE PRECISION NOT
NULL
Difference between busy value from last
sample for the same object.
rcount
DOUBLE PRECISION NOT
NULL
Total number of reads since the object was
first created or restarted.
d_rcount
DOUBLE PRECISION NOT
NULL
Difference between rcount value from last
sample for the same object.
rbytes
DOUBLE PRECISION NOT
NULL
Total number of bytes read since the object
was first created or restarted
d_rbytes
DOUBLE PRECISION NOT
NULL
Difference between rbytes value from last
sample for the same object.
rerror
DOUBLE PRECISION NOT
NULL
Total number of read errors since the object
was first created or restarted
d_rerror
DOUBLE PRECISION NOT
NULL
Difference between error value from last
sample for the same object.
rdrops
DOUBLE PRECISION NOT
NULL
Total number of dropped reads since the
object was first created or restarted.
d_rdrops
DOUBLE PRECISION NOT
NULL
Difference between rdrops value from last
sample for the same object.
rticks
DOUBLE PRECISION NOT
NULL
Total number of ticks (microsecs) taken by
read operations since the object was first
created or restarted.
Table 10-19. Common Performance Columns
Column
Type
Comment