10.23
The Sample Data and Inventory Tables
System Reporter 2.8
3PAR System Reporter User’s Guide
wwn
CHAR(16) NOT NULL
The WWN of the VV.
snp_cpg_name
VARCHAR(32) NOT NULL
The name of the CPG, if any, that is
associated with the VV’s snapshot
space. If the VV snapshot space is not
associated with a CPG, this column is
“-”.
usr_cpg_name
VARCHAR(32) NOT NULL
The name of the CPG, if any, that is
associated with the VV’s user space. If
the VV user space is not associated
with a CPG, this column is “-”.
provv_type
VARCHAR(32) NOT NULL
The provisioning type of the VV (see
the Prov column for the showvv CLI
command in InForm OS 2.3.1 or later).
vv_type
VARCHAR(32) NOT NULL
The VV Type (see the Type column for
the showvv CLI command for InForm
OS 2.3.1 or later).
copyof
VARCHAR(32) NOT NULL
The name of the VV that this VV is a
copy of.
vv_state
VARCHAR(32) NOT NULL
The state of the VV.
createtime
VARCHAR(32) NOT NULL
The creation time for the VV.
spacecalctime
VARCHAR(32) NOT NULL
Only useful for snapshots. The most
recent time that updatesnapspace was
run for the VV.
vsize_mb
DOUBLE PRECISION NOT
NULL
Virtual size of the VV in MB.
Table 10-15. vvspace_
Column
Type
Comment
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (93 pages)
- Data Protector Express Basic-Software (83 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)