Defining MSA array objects
Use the Array Configuration Utility (ACU) to define at least one internal MSA array object (for instance,
“A”) when first setting up the array. After defining an array object, specify LUs within that array object.
Figure 58
Defining MSA array objects with the ACU
Calculating MSA LU size and defining LUs
The ACU used for configuring the MSA uses an optimization algorithm to calculate the user size of a new
LU given a user-specified size in MB (
). Because you cannot bypass or disable the optimization
algorithm, you must compensate for this optimization so that MSA LUs are created at the correct size.
When requesting a new LU through the ACU, make the request 2 to 3 MB larger than needed for
presentation to the XP10000/XP12000. For example, suppose you want to create a 40 GB (40960 MB)
LU on the MSA for use as XP10000/XP12000 external storage. If you request only the exact size needed,
the ACU optimizes the LU to a size of 40959 MB, which is 1 MB smaller than needed. In this case, the