System parameter for external disk arrays, Thunder 9500v series subsystem – HP StorageWorks XP Remote Web Console Software User Manual
Page 78
![background image](/manuals/396884/78/background.png)
78
External Storage XP for the XP10000/XP12000
System parameter for external disk arrays
Thunder 9500V Series subsystem
explains whether to specify system parameters when making settings on ports on the Thunder
9500V Series subsystem.
The Discovery operation
cannot be performed.
Correct the error and retry the operation.
The source of the error could be one of the following:
•
Command View XP or XP Remote Web Console is not in Modify mode.
•
The local disk array port and external disk array port are not connected using
FC cables.
•
Port security is improperly set on the external disk array.
•
The status of the device in the external disk array is not Normal.
•
The external disk array is not connected to a local disk array port set to
External.
•
The external LUN of the local disk array does not have a status of Normal.
•
The external LU capacity is insufficient (less than 46.86 MB).
•
The cable to the switch is not properly connected.
•
The zoning for the switch is not set properly.
If none of these correct the problem, disconnect and then reconnect the cable
between the local disk array and external disk array. After 30 seconds, retry the
operation.
The external LU is blockaded. Correct the error and retry the operation.
The source of the error could be any one of the following:
•
All set paths are blockaded (or not connected).
•
The attribute of the external LU is not set to Read/Write.
•
The external LU is blockaded by an error.
Table 9
General External Storage XP troubleshooting (continued)
Error
Corrective action
Table 10
System parameter settings (Thunder 9500V Series subsystem)
Pane name
Parameter
Parameter setting
System Startup Settings
Start Attribute
•
Single Mode
Specify this parameter when the Thunder
9500V Series subsystem is in the
one-controller configuration.
•
Dual Active Mode
Specify this parameter when the Thunder
9500V Series subsystem is in the
two-controller configuration.
NOTE:
Be sure to specify that Data
Share Mode will be used.
•
Hot Stand-By Mode
Do not specify this parameter.
Common 1
Delay Planned Shutdown
You can either specify this parameter or
omit specifying this parameter.
OPTION 1
SCSI Fibre Channel Common Options
You can either specify this parameter or
omit specifying this parameter.
OPTION 2
SCSI Fibre Channel Common Options
You can either specify this parameter or
omit specifying this parameter.