Figure 28 – HP XP P9500 Storage User Manual
Page 73
![background image](/manuals/396830/73/background.png)
2.
Add the volume association parameters for the Data Exchange volumes to the file.
• Put at least one space between each parameter, and press Return at the end of each line to
separate the parameter sets. All three parameters (device name, volser, LVI type) are case-
sensitive. If you add comments to the file, make sure that each comment line starts with #.
Make sure to enter end on the last line of the file.
3.
When you are done adding the volume association parameters for each Data Exchange volume
to the volume definition file, save your changes and exit the text editor.
/dev/rdsk/cx1tx2dx3sx4
AAAAAA
3390-3A
MFN
MVS1
/dev/rdsk/cy1ty2dy3sy4
AAAAAA
3390-3A
MFN
VOS3
/dev/rdsk/cz1tz2dz3sz4
cccccc
3380-KB
/dev/rdsk/cw1tw2dw3sw4
dddddd
3380-KA
(1)
(2)
(3)
(4)
(5)
(6)
end
(7)
Figure 28 Data Exchange Volume Definition File for Solaris (mto/otm Shown)
.
NOTE:
x = controller number, y = SCSI TID, z = LUN, w = partition (or slice)
/dev/rdsk/cx1tx2dx3
AAAAAA
3390-3A
MFN
MVS
/dev/rdsk/cy1ty2dy3
AAAAAA
3390-3A
MFN
VOS3
/dev/rdsk/cz1tz2dz3
cccccc
3380-KB
/dev/rdsk/cw1tw2dw3
dddddd
3380-KA
(1)
(2)
(3)
(4) (5)
(6)
end
(7)
Figure 29 Data Exchange Volume Definition File for HP-UX (oto Shown)
.
NOTE:
In cxtydz, x = controller number, y = SCSI TID, z = LUN. In OPEN-x, x = 3, 8, K, E, L, M, 9, or V.
/dev/rhdiskn1
AAAAAA
3390-3A
MFN
MVS
/dev/rhdiskn2
AAAAAA
3390-3A
MFN
VOS3
/dev/rhdiskn3
cccccc
3380-KB
/dev/rhdiskn4
dddddd
3380-KA
(1)
(2)
(3)
(4)
(5)
(6)
end
(7)
Figure 30 Data Exchange Volume Definition File for IBM AIX (mto/otm Shown)
.
NOTE:
n = disk ID number (note that the first, second, and third drives are 0, 1, and 2).
HP StorageWorks P9000 Data Exchange User Guide
73