Environment variable for interval time, Display window for interval function, 48 display window for interval function – HP XP P9500 Storage User Manual
Page 48: Display window for the interval function
![background image](/manuals/396830/48/background.png)
Environment Variable for Interval Time
You can specify an interval time after the OtM transfer completes by setting environment variable
(FCU_OTM_INTERVAL).
on page 48 shows the relationship between the environment variable
(FCU_OTM_INTERVAL) and interval time.
Table 26 Relationship between FCU_OTM_INTERVAL and Interval Time
Interval time
FCU_OTM_INTERVAL
The interval function is not available. OtM transfer completes immediately.
No definition
OtM transfer completes after a specified interval time passes.
Value between 60 and 600
(seconds)
The interval function is not available. OtM transfer completes immediately.
Other value
Display Window for Interval Function
The interval function for OtM transfer completion displays interval processing.
shows an example of its display window.
# fcunw -nc -P otm a.dat VSN:DSN EA No LF
otm a.dat VSN:DSN EA No LF Emp=No RDW=No VSE=No PIPE=No
Now checking ...
Start
Processing ( 40%)
Processing ( 80%)
OTM Interval ...
Complete
#
Figure 22 Display Window for the Interval Function
.
About Data Exchange Operations
48