Recommended Actions

Error Message and Description

Error

Code

Make sure that the size of the code conversion
table is 256 bytes.

Code conv. table: File size error

The size of the code conversion table is
not correct.

-235

Check the contents of the input file, especially
the delimiters.

Code conv. table function: Invalid argument

No source data to be converted was
found.

-236

If you do not specify EA or No for the code
conversion option, make sure to specify the
correct file name of your code conversion table.

Code conv. table name: No data

The file name of the code conversion
table is not specified.

-238

Check the source data length and the target re-
cord length, and make sure that the record
length is correct for the source data entities.

Data error: Invalid record length

The data length is not correct for the
FXotm padding function.

-300

For FXotm with padding, make sure that the
target dataset has a fixed-length record format.

Dataset error: Invalid record format

The record format is not correct for the
FXotm padding function.

-301

If padding=Yes for an FXotm operation, the de-
limiter option must be CR, LF or CRLF.

Parameter error: Delimiter error

The delimiter setting is not correct for
the FXotm padding function.

-302

Display the error code using the Help-Error
command. If a FAL error code is displayed, see

Table 65

on page 150. If a system error code is

displayed, see the OS user manual. For ex-
ample, if the partition name does not match the
partition name in the volume definition file, sys-
tem error code 6 (No such device) is displayed.

Dataset: Open error

An error occurred when opening the
dataset.

-319*

Do not specify the RDW option for FXotm oper-
ations.

O to M error: RDW is not supported

-324

Display the attribute information using the Help-
MF-File command. The DO type must be SAM.

Dataset error: Invalid organization type

The DO type of the dataset is not
supported.

-340

Display the attribute information using the Help-
MF-File command. The RF type must be fixed-
length or variable-length.

Dataset error: Invalid record format

The RF of the dataset is not supported.

-341

Display the attribute information using the Help-
MF-File command. The block length must be
nonzero and cannot be greater than 32 kB.

Dataset error: Invalid block length

The block length of the dataset is
invalid.

-342

HP StorageWorks P9000 Data Exchange User Guide

161