Recommended Actions
Error Message and Description
Error
Code
Display the attribute information using the Help-
MF-File command. The record length must be
nonzero and cannot be greater than 32 kB.
Input file error: Invalid record length
The record length of the dataset is
invalid.
-343
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
Input file: Open error
An open error occurred in the input
UNIX file.
-350*
Display the error code using the Help-Error
command. If a FAL error code is displayed, see
on page 150. If a system error code is
displayed, see the OS user manual.
Output file: Open error
A file open error occurred in the output
dataset.
-351*
Collect information such as the error log for
troubleshooting.
Input file: Get file data error
A data acquisition error for the input file
occurred during an FXotm operation.
-352
Collect information such as the error log for
troubleshooting.
Processing data: Length check error
A data length to be processed in the
FXotm operation does not match.
-353
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
Buffer: Memory allocation error
Memory allocation failed.
-355
Display the error code using the Help-Error
command. If a FAL error code is displayed, see
on page 150. If a system error code is
displayed, see the OS user manual.
Input file: Read error
A read error occurred in the input UNIX
file.
-360*
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
Output file: Write error
A write error occurred in the output
dataset.
-361*
Display the error code using the Help-Error
command. If a FAL error code is displayed, see
Output file: Code conversion error
An error occurred in the code
conversion to the output dataset.
-362
Display the error code using the Help-Error
command. If a FAL error code is displayed, see
on page 150. If a system error code is
displayed, see the OS user manual.
Get processing data error
The acquisition of processing data
failed.
-363
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
Input file: Close error
A file close error occurred in the input
UNIX file.
-370
Troubleshooting
162