HP XP P9500 Storage User Manual
Page 159
Recommended Actions
Error Message and Description
Error
Code
Check the specified directory name.
UNIX file: Not a directory
The specified name is not a directory
name.
-181
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
UNIX/Open system file: Open directory error
A directory open error occurred.
-182*
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
UNIX/Open system file: Close directory error
A directory close error occurred.
-183
The input file name must be specified when you
select File-Save.
Input file name: No data
The input file name is not specified.
-190
The output file name must be specified when
you select File-Save.
Output file name: No data
The output file name is not specified.
-191
The FCU parameter definition file name must be
specified when you select File-Save.
Parameter file name: No data
The parameter definition file name is not
specified.
-192
The next time you select File-Load, the first set
of parameters will be loaded.
Parameter file: End line
The last parameter set was loaded from
the parameter definition file.
-200
Make sure that the direction (mto or otm) is
correct.
Parameter file: Direction error
The data transfer direction specified in
the parameter file is incorrect.
-201
The FCU parameter definition file can only store
a maximum of 100 parameter sets. If necessary,
delete one or more parameter sets to make room
for a new parameter set.
Parameter file: Too many data
The number of parameter sets for
parameter definition file exceeded 100.
-202
Make sure that the Emp=Yes/No parameter is
correct.
Parameter: Empty select error
The Emp parameter is incorrect.
-203
Make sure that the RDW=Yes/No parameter is
correct.
Parameter: RDW select error
The RDW parameter is incorrect.
-204
Code conversion cannot be performed when
RDW=Yes. Change the code conversion para-
meter to No.
RDW error: CODE_CONV not supported
Code conversion is not specified as No
when RDW=Yes.
-205