beautypg.com

HP XP P9500 Storage User Manual

Page 168

background image

Recommended Actions

Error Message and Description

Error

Code

Check the system error.

External table file: Close error

The code conversion table could not be
closed.

-223

For FXotm with the padding function, make sure
that the delimiter option is specified as Yes (or
set padding=No).

Parameter: Direction, PAD, and DEL not matched

The combination of otm direction,
PAD=Yes, and DEL=No is not allowed.

-240

When the Data Exchange data transfer direction
is otm, make sure that the RDW option is spe-
cified as No.

Parameter: Direction and RDW not matched

The combination of otm data transfer
direction and RDW=Yes is not allowed.

-241

When the code conversion option is EA or
File_name, make sure that the RDW option is
specified as No. When RDW=Yes, the code
conversion option must be specified as No.

Parameter: Code conv. and RDW not matched

The combination of RDW=Yes and a
code conversion other than No is not
allowed.

-242

When the padding option is specified as Yes,
make sure that the RDW option is specified as
No.
When the RDW option is specified as Yes, make
sure that the padding option is specified as No.

Parameter: Padding and RDW not matched

The combination of RDW=Yes and
padding=Yes is not allowed.

-243

When the delimiter option is specified as Yes,
make sure that the RDW option is specified as
No.
When the RDW option is specified as Yes, make
sure that the delimiter option is specified as No.

Parameter: Delimiter and RDW not matched

The combination of RDW=Yes and
delimiter=Yes is not allowed.

-244

Check whether specified VOLSER is defined in
the volume definition file.

Parameter : Specified VOLSER isn’t defined
Volume Definition file.

Specified VOLSER is not defined in the
volume definition file.

-245

Specify a record length that is less than 3,200
characters (do not include the delimiter).

Parameter definition file : Length error

The record length in the parameter
definition file is too long.

-300

Specify an input/output dataset name that is
less than 1,025 characters.

Mainframe file name : Length error

An input dataset name (in the case of
FXmto) or an output dataset name (in
the case of FXotm) in the parameter
definition file is too long.

-301

Troubleshooting

168