Profile – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 71

Command line 71
Item
Description
Direction (optional) The direction of network traffic on the port being monitored. Valid values include
"ToServer", "FromServer", and "Both".
Examples
->set port-monitor AnalyzerPort=enc0:3:1 Speed=1Gb
Duplex=half
Modifies network analyzer uplink port properties
->set port-monitor MonitorPort=enc0:1:6 Direction=ToServer
Modifies a monitored server port
->set port-monitor Enabled=true
Enables port monitoring
->set port-monitor Enabled=false
Disables port monitoring
Item
Description
show port-monitor
Display the Virtual Connect port monitor configuration.
Syntax
show port-monitor
Example
->show port-monitor
Displays the port monitor configuration
profile
Manage server profiles.
Supported actions: add, assign, copy, help, load, remove, save, set, show, unassign
Item
Description
add profile
Create a new server profile. After the profile is created, the profile can be
configured using the "set" subcommand, and additional network, fabric, and FCoE
connections can also be added. The server profile can also be assigned to a device
bay using the assign subcommand.
Syntax
add profile
[-NoDefaultFcConn] [-NoDefaultFcoeConn] [Nag=
[SNType=
[SerialNumber=
Parameter
ProfileName
The unique name of the new server profile to create
Options
NoDefaultEnetConn
Do not add default Ethernet network connections when creating the server profile.
NoDefaultFcConn
Do not add default FC SAN connections when creating the server profile.
NoDefaultFcoeConn
Do not add default FCoE SAN connections when creating the server profile.
Properties
Nag (optional)
The network access group for the profile. The default is the domain Default network
access group.
SNType (optional)
The source of the serial number assignment to be used during the profile creation.
If not specified, the serial number is assigned according to the Virtual Connect
default domain settings. Valid values include "Factory-Default" and "User-Defined".
SerialNumber
(required if the
SNType is
A custom user-defined serial number associated with the server profile. When the
profile is assigned to a device bay that contains a server, the server inherits the
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem